Home-knowledge-

Content

Alpha Lipoic Acid Bulk: Two CAS Entries, One Assay

Nov 18, 2026

Candy
Candy
Quality & Analytical Manager with 10+ years of experience. Expert in analytical method development and validation (e.g., HPLC), ensuring raw materials and final products meet global quality standards.

Two pages in our own catalogue describe alpha lipoic acid, and they do not agree. The alpha lipoic acid page prints CAS 62-46-4, an assay of 98–102% and the form described as racemic. The other prints CAS 1077-28-7 and an assay of 99%, and says nothing about the form. Same slightly yellow crystalline powder, same test method, two registry entries. A buyer holding a certificate from either page has to establish which entry the document cites, and that question is what this article is about.

01 Two Pages, Two CAS Entries: Which One Does Your Certificate Cite?

Why can one material carry two registry entries across two pages?

A registry entry identifies a substance as that register defines it. It is not a grade, not a purity and not a statement of form. Two entries can therefore sit beside two descriptions without either being a typing error - and, equally, one of them can be the wrong entry for the article actually being sold. A product page cannot settle that. The certificate and the supplier's written declaration are the only documents that can.

Which entry should a certificate carry?

The one that matches the article being released. A certificate is a statement about a specific drum, and its first job is to say what that drum contains. If the header cites one entry while the body describes a form normally associated with another, the document is not yet a certificate of anything; it is a template with a figure filled in.

What should a buyer do before comparing the two pages?

Ask both suppliers, in writing, which entry their certificate cites and which form they are shipping. Do not ask which is correct. Ask which is being shipped. The first invites an opinion you cannot hold anyone to; the second is a statement of fact that travels with the lot.

Fieldlipoic-acid page99-pure pageWhat to confirm before booking
Registry entryCAS 62-46-4CAS 1077-28-7Which entry the certificate cites
Assay98–102%99% (98.0–101.0%)Whether both bounds are enforced
FormRacemicNot statedThe form on the lot, in writing
Test methodHPLCHPLCThe conditions behind the figure
AppearanceSlightly yellow crystalline powderSame wordingColour against a retained sample
Packing25 kg fibre drum1 kg foil bag, 25 kg drumUnit, inner layer, and the lot drawn from

The table repeats what each page states and nothing more. It does not establish a relationship between a registry entry and a form, and it should not be read as one: the pairing is exactly what the certificate has to settle, which is why the fourth column exists.

02 What 98–102% Measures, and What 99% Measures

Is 98–102% an assay range or a minimum?

On a specification, a range normally means the release window: a lot outside either bound is not released against that line. Whether the supplier enforces both ends, or only the lower one, is a separate question and it belongs in your own specification rather than in theirs.

How does a single 99% figure differ from a 98–102% figure?

They are two conventions for nearly the same window, and the difference sits at the ends: the first closes at 102 and the second at 101. The second page carries its band in brackets rather than in the headline, which is a formatting habit rather than a looser claim. Two quotations written in different conventions are not comparable until both are restated as a window with the method named, as the 99% grade page does in its own line.

03 Racemic Against R-Alpha-Lipoic Acid: Two Different Articles

Are the two forms the same article?

No. One is a mixture of two mirror-image forms in equal proportion; the other is a single one of them. They are different articles with different names, and a quotation that does not say which it covers has not named the article at all, whatever figure it prints.

How can a buyer tell them apart on paper?

Only from the declaration. The appearance line will not separate them and neither will the assay figure, because both can be met by either article. Ask for the form in the same sentence as the name, and require it on the certificate rather than in the covering email. Our notes on another material sold as a single article, d-chiro-inositol, follow the same order.

alpha lipoic acid 99% assay bulk powder
Figure 1 - Slightly yellow powder as the specification sheet declares it, the appearance line that rides beside the assay.

04 HPLC as the Test Method: What the Chromatogram Does and Does Not Show

What does a chromatogram actually show?

A separation with a detector, reported as a figure against a calibration run under the same conditions. It shows that the prepared sample ran as a main peak, and how much of the integrated area that peak carries. Everything the figure means is contained in the phrase "under the same conditions".

Can the method distinguish the two forms?

Not by default. A column separates what the stationary phase and the run resolve, and a method written to produce one peak will usually report one peak regardless of composition. If the form matters to your process, the question has to be put to the method by name and answered with a reference standard - it cannot be inferred from the figure.

alpha lipoic acid COA and test method
Figure 2 - A chromatography system in the QC laboratory, where the assay figure printed on a certificate is produced.

05 Slightly Yellow Crystalline Powder: Light, Heat and Packing

Does light sensitivity change how the material is packed?

It changes what the packing has to do. A light-sensitive powder needs an inner layer that blocks light, and a declaration that says so. Whether the standard drum already provides one is a question for the supplier, not a property you can read off the powder.

What does the appearance line actually tell you?

It describes a colour and a habit. Both are useful as lot-to-lot checks against a retained sample, and neither identifies the article. A tint that deepens across successive shipments is a question about storage and handling rather than evidence of a different grade.

06 A 25 kg Fibre Drum or a 1 kg Foil Bag: What the Unit Changes

Does the pack unit change the specification?

No. It changes the sampling question. A production unit and a sample unit are drawn at different points in the process, and the certificate that travels with a bag may describe a lot rather than the bag itself.

Is the bag drawn from the same lot as the drum?

Ask, and get it in writing. If it is, one certificate covers both and the sample is representative. If it is not, the sample is a separate article and its figure says nothing about the drum you will receive. Our notes on bulk powder packaging draw the same line between a unit and a lot.

Packing is also where a quotation stops being abstract. A drum fixes the outer dimension, the pallet count and the way the material is opened at goods-in; a bag fixes nothing except the unit you will test. Ask which unit the certificate was drawn against before the two are compared at all.

alpha lipoic acid 25 kg fibre drum export packing
Figure 3 - 25 kg fibre drums palletised and wrapped, the unit a quotation is normally written against.

07 Comparing Two Quotations Field by Field

Which fields decide whether two quotations are comparable?

Six: the name with its form, the assay as a window with the method, the registry entry the certificate cites, the appearance line, the pack unit, and the documents due per lot. Two alpha lipoic acid quotations that agree on the figure and disagree on any of the other five are not quotes for the same article.

What if one quotation names a form and the other does not?

Then the second has not named the article, and the comparison has to wait. Put the request in writing and read an unanswered request as a reason to hold the comparison, not as a reason to assume the two are identical.

08 Documents to Request Before You Book

Which documents should arrive before a booking?

Four: the specification sheet, the certificate for the lot offered, the packing statement with the inner layer named, and a written declaration of the form. The certificate carries the most weight, because it is the only document that sets a registry entry beside a measured figure. Reading it line by line is the exercise described in our notes on a chondroitin sulfate COA.

09 What to Put in Your Own Purchase Specification

Which lines belong in your own purchase specification?

Six, written before you request anything: the name with the form, the assay as a window plus method, the registry entry you require to be cited, appearance against a retained sample, the pack unit and its inner layer, and the documents due per lot. Each line removes a question that would otherwise arrive after the order; the last removes the argument about which document governs. Applied to qualifying a supplier rather than a single lot, the same discipline is set out in our notes on verifying a plant extract supplier.

Write the six lines before the first email rather than after the first certificate. A specification that names the form and the entry comes back answered precisely; one that asks for alpha lipoic acid and leaves the rest open comes back as a quotation that has to be re-read line by line before it means anything.

10 Frequently Asked Questions

Why do two supplier pages list different CAS numbers for alpha lipoic acid?

Because a registry entry identifies a substance rather than a grade, two entries can appear beside two descriptions without either being a typo, and one of them can still be the wrong entry for the article sold. The page cannot resolve it; the certificate and the written declaration can.

Is 98–102% an assay range or a minimum?

As printed, a range. Whether both ends are enforced at release is a question for the supplier, and it is worth writing your own lower bound rather than inheriting theirs.

Does a 99% figure mean the same thing as a 98–102% figure?

Nearly, but not exactly: the lower bounds match and the upper bounds do not. Restate both as a window with a method before reading them as one number.

How do I know whether a quotation is racemic or R-alpha-lipoic acid?

From a written declaration, not from the figure or the appearance. Ask for the form in the same sentence as the name and require it on the certificate.

Does light sensitivity change how the material is packed and shipped?

It changes the inner layer, and it may change the outer pack. Ask which layer the standard unit uses and whether that is the same unit offered for export.

What should my purchase specification state?

The six lines above: name with form, assay window with method, the registry entry to be cited, appearance against a retained sample, pack unit and inner layer, and the documents due per lot.

11 Request a Specification Sheet

If you are qualifying alpha lipoic acid, tell us the form you need, the assay window your process requires, and the pack unit you will receive. We will send the specification sheet for that grade, the certificate for the lot we would ship, and a written statement of the registry entry it cites - so the three agree before anything is booked.

Email liu@wellgreenxa.com or message us on WhatsApp. We reply within 24 hours. If you already hold a certificate from another supplier, send it with your target window; naming the two lines that do not match is faster than rebuilding the specification from the start.

---
SEND INQUIRY

SEND INQUIRY